Improve the accuracy of the CBE display

Many manufacturers use displays from CBE in their vehicles. Most of these displays have a very "coarse" resolution and can only show 25% steps (0 - 25 - 50 - 75 - 100%). If you have installed SuperSense it is recommended to increase the accuracy of the display.


Note: The following instructions may vary slightly depending on the display and software version.


To do this, carry out the following steps:

  1. Press the "PROG" button
  2. Keep the adjustment button (wrench / screwdriver) pressed until a short beep is heard.
  3. Now briefly press the button to the left of the wrench / screwdriver once
  4. Now press the button 1x briefly with the wrench / screwdriver
  5. Now open the menu item "TANKS
  6. Select a tank
  7. Now you can set the resolution to "%5" to get 5% steps. The setting "STAND" does not need to be changed.


Further articles

Adjusting the length of the sensor tube
Mounting type B: Directly in (drain) pipe
Level measurement without app or display